Yes, you can move washer and dryer hookups, but it’s a plumbing, electrical and venting job, not just a matter of sliding the machines over. The new spot needs a drain at the right height, hot and cold water, a dedicated laundry circuit, and a dryer exhaust that runs outdoors within code limits. Check with your local building department about permits before you start, and hire licensed trades for gas and electrical connections.

Last updated: November 14, 2026.

Below: what a new laundry location needs, the code rules for dryer vents and laundry circuits, drain height requirements from washer makers, the safety points for gas dryers, and a planning checklist. Related guides: does a washer drain need a vent, does a washer need a dedicated circuit and do dryers have to be vented outside.

What a new laundry location needs

Hookup What the new spot needs Who usually does it
Drain A standpipe, wall drain or laundry tub at a height your washer accepts Plumber
Water supply Hot and cold supply valves within reach of the washer’s hoses Plumber
Washer power A receptacle on a 20-amp laundry branch circuit Electrician
Dryer power The outlet type your dryer’s instructions call for Electrician
Gas (gas dryers only) A gas line and connection free of leaks Qualified gas professional
Dryer exhaust A metal duct to the outdoors within the code’s length limit Contractor or HVAC

Dryer exhaust: the rules that limit where a dryer can go

The dryer vent often decides whether a new location works. The International Residential Code (shown here in a 2021-based edition on UpCodes) sets these rules in section M1502:

  • Terminate outdoors. Exhaust ducts must end outside the building, per the dryer maker’s instructions, or at least 3 feet from openings into the building if the instructions don’t say. The termination needs a backdraft damper and no screen.
  • Use smooth metal duct. Ducts must have a smooth interior, be at least 0.0157 inch (No. 28 gauge) metal and be 4 inches in diameter.
  • Keep it short. The maximum exhaust duct length is 35 feet from the transition duct connection to the outdoor terminal, and every fitting reduces that. For example, a 4-inch radius mitered 90-degree elbow counts as 5 feet.
  • Transition duct limits. The flexible connector from dryer to wall must be a single listed length, no more than 8 feet, and not concealed in walls.
  • No booster fans. Domestic booster fans aren’t allowed in dryer exhaust systems.
  • Protect the duct. Steel shield plates are required where nails or screws could pierce the duct.

The code exempts listed condensing (ductless) dryers from the outdoor exhaust rule. EPA also advises venting moisture-producing appliances such as clothes dryers to the outside where possible, to help control indoor humidity and mold.

Electrical: the laundry circuit

The IRC (section E3703.3, matching NEC 210.11(C)(2)) requires at least one 20-amp branch circuit for laundry-area receptacles, and that circuit can serve only receptacles in the laundry area. Electric dryers have their own power needs, so follow the dryer’s installation instructions for the outlet type. NFPA’s dryer safety tips say to make sure the right plug and outlet are used and the machine is connected properly, and that dryers should be properly grounded.

Washer drain: height matters

Your washer’s installation guide sets the drain height range. Two examples:

Maker Requirement
GE (full-size top-load) Discharge height at least 30 inches and no more than 8 feet above the washer’s base
GE (full-size front-load) At least 24 inches and no more than 8 feet
Samsung Drain hose at least 18 inches high (24 inches for wash basins) and no higher than 96 inches; inserted 6 to 8 inches into the standpipe, secured, and not airtight

GE notes that its washer pumps can push water up to 8 feet, but each extra foot of height reduces the flow rate by about 1 gallon per minute. Samsung warns against using a drain hose extension kit.

Gas dryers

NFPA says gas dryers should be inspected by a qualified professional to make sure the gas line and connection are intact and free of leaks. If moving the dryer means extending the gas line, have a licensed professional do that work.

Permits and inspections

Moving plumbing, adding a circuit and cutting a new vent through a wall or roof can all require permits and inspections, and the rules vary by city and county. Call your local building department before you start. NFPA also recommends having your dryer installed by a professional.

You may have read that moving laundry hookups is a simple weekend project. It touches the drain, supply, electrical and venting systems, so plan it as a small renovation.

Planning checklist

  1. Measure the dryer exhaust route to an outside wall and count the elbows against the 35-foot limit.
  2. Confirm a drain can be placed at a height your washer accepts.
  3. Check your electrical panel has room for a 20-amp laundry circuit and the dryer’s circuit.
  4. For a gas dryer, confirm a gas line can reach the new spot.
  5. Think about floor protection. Our guide to washer drain pans covers when one makes sense.
  6. Check permit requirements, then hire licensed trades.

Frequently asked questions

Can I move my washer and dryer to another room?

Yes, if the new room can get a proper drain, water supply, a 20-amp laundry circuit and a code-compliant dryer exhaust. Check local permit rules first.

How long can a dryer vent be?

The IRC allows 35 feet from the transition duct connection to the outdoor terminal, minus an allowance for each fitting.

How high does a washer drain need to be?

It depends on the model. GE’s full-size top-loaders need 30 inches to 8 feet; Samsung lists 18 to 96 inches.

Can I do it myself?

Gas and electrical work should be done by licensed professionals, and NFPA recommends professional dryer installation.

Sources